Unsere Gruppe organisiert über 3000 globale Konferenzreihen Jährliche Veranstaltungen in den USA, Europa und anderen Ländern. Asien mit Unterstützung von 1000 weiteren wissenschaftlichen Gesellschaften und veröffentlicht über 700 Open Access Zeitschriften, die über 50.000 bedeutende Persönlichkeiten und renommierte Wissenschaftler als Redaktionsmitglieder enthalten.

Open-Access-Zeitschriften gewinnen mehr Leser und Zitierungen
700 Zeitschriften und 15.000.000 Leser Jede Zeitschrift erhält mehr als 25.000 Leser

Abstrakt

First Use of an Ingestible Sensor to Manage Uncontrolled Blood Pressure in Primary Practice: The UK Hypertension Registry

Naik R, Macey N, West RJ, Godbehere P, Thurston SC, Fox R, Xiang W, Kim Y, Singh I, Leadley S, DiCarlo L

Background: Primary care physicians used a CE-marked ingestible sensor in a real world setting to assess patients with persistent hypertension. The objectives were to (1) characterize the pattern of their medication use, (2) differentiate medication use from pharmacologic unresponsiveness as a potential underlying cause for uncontrolled hypertension; (3) categorize and summarize subsequent management decisions; and (4) assess the usability and acceptability of passive electronic monitoring for managing hypertension.

Methods: There were 167 patients with uncontrolled hypertension whilst chronically prescribed 2 to 5 antihypertensives; 40% were chronically prescribed ≥ 3 antihypertensives. Patients were instructed to ingest a pharmacologically inert tablet containing the ingestible sensor whenever they took their prescribed medications. A wearable sensor on the patient's torso passively recorded the dates/times of tablet ingestion. Taking adherence (i.e., the total number passively detected divided by the total number prescribed) and timing adherence were determined for a period of two weeks with no change in therapy.

Findings: Taking adherence ranged from 53-100%; timing adherence ranged from 21-100%. Systolic blood pressure decreased from 154 ± 13 to 145 ± 18 mmHg (mean -9.7 mmHg; 95% CI: -12.5, -7.0 mmHg, p<0.001). Diastolic blood pressure decreased from 85 ± 11 to 80 ± 12 mmHg (mean -5.0 mmHg; 95% CI: -6.5, -3.5 mmHg, p<0.001). Thirty-two percent (32%) of participants achieved their treatment goals using their existing therapy. Subsequent management included: medication reviews and/or adherence counseling with no anti-hypertensive changes in 81%, anti-hypertensive changes in 13%, referrals to specialists in 1%, and no additional actions were taken in 6%. Practitioners found the offering easy to utilise, and the majority of patients expressed a positive experience in using it.

Conclusion: In patients with uncontrolled blood pressure, the inclusion of an ingestible sensor in everyday practice helped practitioners to identify potential factors contributing to persistent hypertension and to determine subsequent patient-specific interventions.