Unsere Gruppe organisiert über 3000 globale Konferenzreihen Jährliche Veranstaltungen in den USA, Europa und anderen Ländern. Asien mit Unterstützung von 1000 weiteren wissenschaftlichen Gesellschaften und veröffentlicht über 700 Open Access Zeitschriften, die über 50.000 bedeutende Persönlichkeiten und renommierte Wissenschaftler als Redaktionsmitglieder enthalten.
Open-Access-Zeitschriften gewinnen mehr Leser und Zitierungen
700 Zeitschriften und 15.000.000 Leser Jede Zeitschrift erhält mehr als 25.000 Leser
Nadia Abdulla Batawil
Objectives: In patients who have parathyroid adenoma, combination of ultrasonography and technetium Tc 99m sestamethoxyisobutylisonitrile scan (also called sestamibi or MIBI scan), which allows anatomic and functional information about parathyroid adenomas, is used commonly to maximize operative cure. The sensitivity of MIBI scan may be increased by adding single photon emission computed tomography (SPECT) and computed tomography (CT) as a combined MIBI-SPECT CT scan. We assessed the accuracy of ultrasonography and parathyroid MIBISPECT scan in detecting parathyroid adenoma and evaluated the potential benefit of the combined protocol of ultrasonography and MIBI-SPECT parathyroid scan.
Methods: In 58 patients who had biochemical evidence of primary hyperparathyroidism, we retrospectively reviewed the preoperative ultrasonography and MIBI-SPECT scans. The results of these studies were correlated with surgical findings.
Results: In the 58 patients, surgery showed that 43 patients (74%) had solitary parathyroid adenoma. The sensitivity, specificity and accuracy of MIBI-SPECT for parathyroid adenoma was (72%,80%,74%) and for ultrasonography (53%,60%,55%) respectively. The highest sensitivity is noted with the combination of MIBI-SPECT and ultrasonography (79%), . 9 adenomas (21%) were missed by both modalities. In the 20 adenomas that were missed by ultrasound 11 were detected by MIBI SPECT.
Conclusion: The MIBI-SPECT had better performance than ultrasonography for parathyroid adenoma localization. The combined MIBI SPECT and ultrasonography has the highest sensitivity for parathyroid adenoma detection (79%). An alternative strategy may be to use MIBI-SPECT initially, and to proceed to ultrasonography only in patients with negative MIBI- SPECT. This may avoid many ultrasonography procedures.